In the event the switch trips, the ReStart devices, after checking the system status, restore the power supply thereby ensuring maximum continuity of service in complete safety. Available for both residual current circuit breakers and residual current circuit breakers with overcurrent protection, the range is characterized by the Autotest functions, with periodic and automatic control of the residual current protection without interrupting the power supply and PRO with extended control of the system.
YOUR SEARCH
ReStart Autotest
ReStart Autotest 2 poles - Versions coupled with RCCB's
Automatic reclosing devices with preventive check of the insulation and automatic test of the residual current circuit breaker - PRO version
CHARACTERISTICS: after RCCB has tripped, ReStart checks the insulation prior to the automatic reclosure. In the event of a fault (earth leakage), ReStart will not reset the circuit breaker but will continue to monitor the circuit every 2 minutes reclosing the circuit breaker when safe to do so. In the meantime the integrated configurable auxiliary contact will change state to indicate that the automatic reset did not take place.
Compatible with:
-GWD0953 WiFi Interface Module
-GW90992 ModBus RS485 interface module. NOTE: the Autotest function automatically and periodically (every 28 days) tests the RCCB, without interrupting the electric power supply, thus maintaining the performance of the residual current protection over time.
230 V ac power supply, phase-neutral.
RCCB's type B and A[IR] Impulse Resistant presents greater resistance to untimely tripping in comparison to standard residual current circuit breakers. Immunity level 8/20µs: 3000A for IR type, 250A for standard type.
ReStart Autotest 4 poles - Versions coupled with RCCB's
Automatic reclosing devices with preventive check of the insulation and automatic test of the residual current circuit breaker - PRO version
CHARACTERISTICS: when the' RCCB switch trips, ReStart performs' the isolation check before the automatic reset. In the event of a ground fault, ReStart does not reset'the switch but continues to check the'system every 2 minutes until, once the safety conditions are restored, it resets the'switch. The auxiliary contact that can be configured and integrated in the meantime switches on to signal the failure of automatic resetting.
Coupled with: -WiFi interface
module GW90954 -ModBus RS485 GW90992 interface
module. NOTE: the SELF-TEST function automatically and periodically (every 28 days) tests the RCCB without cutting off power to the'system to maintain the' efficiency of the RCCB protection over time.
Reinforced Immunity Type A[S], B and A[IR] circuit breakers are equipped with greater resistance to unexpected trips than standard RCCBs. Immunity level 8/20μs: 3000A for IR versions and S, 250A for standard versions.
ReStart RD
ReStart RD 2 poles - versions coupled with RCCB'S IDP
Automatic reclosing devices with preventive check of the insulation
CHARACTERISTICS: after RCCB has tripped, ReStart checks the insulation prior to the automatic reclosure. In the event of a fault (earth leakage), ReStart will not reset the circuit breaker. NOTE: the ARD must be supplied at 230 Vac phase-neutral.
Automatic reclosing devices with preventive check of the insulation - PRO version
CHARACTERISTICS: after RCCB has tripped, ReStart checks the insulation prior to the automatic reclosure. In the event of a fault (earth leakage), ReStart will not reset the circuit breaker but will continue to monitor the circuit every 2 minutes reclosing the circuit breaker when safe to do so. Compatible with: -GWD0951 auxiliary contact -GWD0953 WiFi Interface Module -GW90992 ModBus RS485 interface module (only if already coupled with GWD0951 auxiliary contact). NOTE: the ARD must be supplied at 230 Vac phase-neutral.
ReStart RD 2 poles - versions to be coupled with RCCB'S IDP
Automatic reclosing devices with preventive check of the insulation
CHARACTERISTICS: after RCCB has tripped, ReStart checks the insulation prior to the automatic reclosure. In the event of a fault (earth leakage), ReStart will not reset the circuit breaker. NOTES. cannot be used with 4P RCCBs in 3 modules and type B RCCBs. the ARD must be supplied at 230 Vac phase-neutral.
Automatic reclosing devices with preventive control of the insulation - PRO version
CHARACTERISTICS: after RCCB has tripped, ReStart checks the insulation prior to the automatic reclosure. In the event of a fault (earth leakage), ReStart will not reset the circuit breaker but will continue to monitor the circuit every 2 minutes reclosing the circuit breaker when safe to do so. Compatible with: -GWD0951 auxiliary contact -GWD0953 WiFi Interface Module -GW90992 ModBus RS485 interface module (only if already coupled with GWD0951 auxiliary contact) NOTES: cannot be used with 4P RCCBs in 3 modules and type B RCCBs. The ARD must be supplied at 230 Vac phase-neutral.
ReStart RD 4 poles - versions to be coupled with RCCB'S IDP
Automatic reclosing devices with preventive control of the insulation - PRO version
CHARACTERISTICS: after RCCB has tripped, ReStart checks the insulation prior to the automatic reclosure. In the event of a fault (earth leakage), ReStart will not reset the circuit breaker but willcontinue to monitor the circuit every 2 minutes reclosing the circuit breaker when safe to do so. In the meantime the integrated configurable auxiliary contact will change state to indicate thatthe automatic reset did not take place.
Compatible with
: -GW90945 WiFi Interface Module
-GW90992 ModBus RS485 interface module. NOTES: they cannot be used with 4P RCCBs in 3 modules. 230 V ac power supply, phase-neutral.
ReStart RM
ReStart RM 2 poles - versions coupled with compact RCBO'S MDC
Automatic reclosing devices with preventive check of the insulation and of the short circuit
CHARACTERISTICS: after RCBO has tripped, ReStart checks the insulation and the short circuit prior to the automatic reclosure.. In the event of a fault (earth leakage or short circuit), ReStart will not reset the circuit breaker. NOTE: the ARD must be supplied at 230 Vac phase-neutral.
Automatic reclosing devices with preventive check of the insulation and of the short circuit - PRO version
CHARACTERISTICS: after RCBO has tripped, ReStart checks the insulation and the short circuit prior to the automatic reclosure. In the event of a fault (earth leakage), ReStart will not reset the circuit breaker but will continue to monitor the circuit every 2 minutes reclosing the circuit breaker when safe to do so. Compatible with: -GWD0951 auxiliary contact -GWD0953 WiFi Interface Module -GW90992 ModBus RS485 interface module (only if already coupled with GWD0951 auxiliary contact). NOTE: the ARD must be supplied at 230 Vac phase-neutral.
ReStart RM 2 poles - versions to be coupled with compact RCBO'S MDC
Automatic reclosing devices with preventive check of the insulation and of the short circuit
CHARACTERISTICS: after RCBO has tripped, ReStart checks the insulation and the short circuit prior to the automatic reclosure. In the event of a fault (earth leakage or short circuit), ReStart will not reset the circuit breaker. NOTE: the ARD must be supplied at 230 Vac phase-neutral.
Automatic reclosing devices with preventive check of the insulation and of the short circuit - PRO version
CHARACTERISTICS: after RCBO has tripped, ReStart checks the insulation and the short circuit prior to the automatic reclosure. In the event of a fault (earth leakage), ReStart will not reset the circuit breaker but will continue to monitor the circuit every 2 minutes reclosing the circuit breaker when safe to do so. Compatible with: -GWD0951 auxiliary contact -GWD0953 WiFi Interface Module -GW90992 ModBus RS485 interface module (only if already coupled with GWD0951 auxiliary contact). NOTE: the ARD must be supplied at 230 Vac phase-neutral.
ReStart RM 4 poles - versions to be coupled with compact RCBO'S MDC
Automatic reclosing devices with preventive check of the insulation and of the short circuit PRO version
CHARACTERISTICS: after RCBO has tripped, ReStart checks the insulation and the short circuit prior to the automatic reclosure. In the event of a fault (earth leakage), ReStart will not reset the circuit breaker but will continue to monitor the circuit every 2 minutes reclosing the circuit breaker when safe to do so. In the meantime the integrated configurable auxiliary contact will change state to indicate that the automatic reset did not take place. Compatible with: - GW90945 WiFi interface module - GW90992 ModBus RS485 interface module NOTE: the ARD must be supplied at 230 Vac phase-neutral.
ReStart RM TOP - Version to be coupled with RCBO's MDC/MT+BD or MCB's MTC/MT
Adjustable automatic reclosing device with/without preventive check of the insulation and/or of the short circuit
CHARACTERISTICS: the Rm TOP ReStart allows to: - set the reclosing mode (reclosing with system check, reclosing by attempts, remote reclosing and excluded reclosing) - adapt the insulation threshold in according to the associated circuit breaker - regulate the reclosing time dealy. The device is equipped with 2 integrated auxiliary contacts of position and/or tripped relay. NOTE: the ARD must be supplied at 230 V ac phase-neutral.
ReStart CM - Motor operating device to be coupled with RCBO's MDC/MT+BD or MCB's MTC/MT
Motor operating device without preventive control of the insulation and of the short circuit
CHARACTERISTICS: the device is equipped with 1 integrated auxiliary position contact or tripped relay. NOTE: the reclosing device must be supplied at 230 V ac phase-neutral.
CHARACTERISTICS: when the circuit breaker trips, thanks to GW96014, it can be reclosed remotely by means the ReStart RM TOP or the motor operating ReStart CM, even before the shunt trip release has been reclosed. ReStart RM TOP and ReStart CM activate a remote reclosing of both the circuit breaker lever and the shunt trip release lever simultaneously. APPLICATIONS: it is used to cause the remote opening of the circuit breaker coupled with the ReStart RM TOP or the motor operating ReStart CM. When using a release associated with ReStart RM TOP, pay attention to the system control and reclose logic set on the ReStart RM TOP. NOTE: when using a ReStart RM TOP, the shunt trip release must be placed between the ReStart RM TOP device and the circuit breaker. When using a ReStart CM, the shunt trip release must be placed to the left of the ReStart CM device. A position auxiliary contact or a fault indication switch can also be added to the left of the release GW96014.
CHARACTERISTICS: the auxiliary contact, coupled on the right side of ReStart device, will change state to indicate that the automatic reset did not take place because there is a fault in the electrical system. The auxiliary contact can be set in three operating modes: - NO (default condition) - NC - NO as signal of handle position NOTE: the auxiliary contacts is free potential type.
CHARACTERISTICS: the Wi-Fi modules (to be coupled on the right side of the ReStart PRO device) if connected to a router, allow the following information to be remoted on devices connected to the internet network:
- status of the' switch (ON/off)
- lack of power supply in the' system due to the presence of a fault
- restoration of the power' supply following the successful automatic reset
- if combined with ReStart Rd/Rm PRO 2P and ReStart Autotest PRO 2P, the consumption related to electricity produced and consumed, active and reactive power, current and voltage of the system
- if combined with Restart Autotest PRO 2P and 4P, the details of the' last Autotest operation (outcome, date and time)
CHARACTERISTICS: the BUS module, by means software available on www.GEWISS.com website, allows to: - monitor the status of circuit breaker coupled with ReStart - control Autotest fuuction remotely - manage automatic reclosing function remotely. APPLICATION: it allows the installation of ReStart device in monitoring systems with BUS RS485 communication protocol.
Gewiss uses its own technical cookies and those of third parties to ensure the proper functioning of the site and for statistical purposes and, subject to your consent, also profiling cookies to offer you a personalized experience and targeted advertising based on the analysis of your navigation. By clicking on "Accept all" you will give your consent to all profiling cookies.
If you close this banner by clicking on the "X", you can continue browsing without profiling cookies being installed. You can always change your preferences, through the functions offered by Gewiss, navigating the "Cookie Policy" page from the link in the footer on every page of the Site. For further information please visit our Privacy Policy and Cookie Policy.
Gewiss and some third parties make use of the cookies present on "gewiss.com".
Gewiss uses its own technical cookies and those of third parties to ensure the proper functioning of the site and for statistical purposes and, subject to your consent, also profiling cookies to offer you a personalized experience and targeted advertising based on the analysis of your navigation. By clicking on "Allow all" you give your consent to all profiling cookies
Manage preferences:
+
Strictly necessary cookies
always active
These cookies are essential to enable you to move around the website and use its features: setting privacy preferences, signing in or filling in forms. Without these cookies, the services you request through the use of our website cannot be delivered correctly. Strictly necessary cookies do not require your consent, in accordance with applicable law. You can configure your browser to block Strictly necessary cookies, but you may not be able to fully utilize all features of the website.
Analytics cookies get leveraged as well and they are considered as technical ones: these cookies allow you to understand how the Site is used. They do not collect information about your identity or any Personal Data. The information is processed aggregately and on anonymous base.
+
Profiling cookies
These cookies are installed after your consent, which you can give by using the features offered by our cookie banner, they are used to track your browsing (including off the Site) and understand your likes and dislikes, in order to be able to show you personalized advertising banners that are relevant to you while you are browsing.
Field required
Check that the e-mail is not already used or that all the fields have been enhanced
Check your email
The password must contain at least 6 and a maximum of 12 characters, a numeric character and a uppercase letter
Registration is successfully completed
Attention: User name and password do not match
Enter a valid email address
The value does not match
Data modification is successfully completed
To fill the form you must be logged. Please go to
login page
Mail sent successfully
Inscribed
Thank you!
Your request has been sent successfully
Authentication error
Error sending request
Please try again later!
User not found
Integration error
Please contact the administrator
You are already registered at the event
View card
Change Password is successfully completed
The password must contain at least 6 and a maximum of 12 characters, a numeric character and a uppercase letter
Please enter the mail in the appropriate field
Error sending request. Please try again later!
Saving in the list
Insert the name of the catalog
Expired
For the download of the file you have to choose a subtype during registration, go on modify profile and choose it!
For the download of the file you have to be a professionist installer or wholesaler. Upgrade your profile on my profile page!
For the download of the file you have to be a professionist installer or wholesaler, a designer or lighting designer. Upgrade your profile on my profile page!
GO
Verify code is expired, please try to login
The date must be of the indicated format
List
Created by
Select
Account not yet confirmed, please confirm the link we sent you by mail