Overview
TECHNICAL INFO
INSPIRATIONS
SUPPORT
 residual current circuit breaker - idp - 4p 80a type ac instantaneous idn=0,03a - 4modules
Datasheet residual current circuit breaker - idp - 4p 80a type ac instantaneous idn=0,03a - 4modules
Photometric diagram gw94761k

RESIDUAL CURRENT CIRCUIT BREAKER - IDP - 4P 80A TYPE AC INSTANTANEOUS Idn=0,03A - 4MODULES

Code: GW94761K
Range: 90 RCD Range
Modular circuit breakers for residual current protection

The 90 RCD range meets any ground fault protection requirement for any area of application. The range comprises MDC compact residual current c.b. with overcurrent protection. (from 6 to 32 A, curves B and C, up to 10 kA and lΔn from 30 and 300 mA type AC, A, A[IR] and A[S] and F) BD and BDHP, add-on residual current devices for circuit breakers MT and MTHP (lΔn from 10 mA to 3 A type AC, A, A[IR], A[S] and A adjustable) IDP residual current circuit breakers (up to 100 A, lΔn from 10 to 500 mA type AC, A, A[IR], A[S], F, B).

Technical Info

Information
Download
Software
Certificates
Description RESIDUAL CURRENT CIRCUIT BREAKER
Code SD
No. of poles 4P
No. modules 4
Rated current 80 A
Rated residual operating current 30 mA
Type AC
Rated voltage (EN/IEC 61008-1, 61008-2-1) 400/415 V
Standard IEC/EN 61008-1, IEC/EN 61008-2-1
Rated frequency (Hz) 50Hz
Insulation voltage (Ui) 400 V
Rated impulse withstand voltage (Uimp) 4 kV
Overvoltage category III
Level of immunity (8/20 μs) 250 A
Section rigid cable Max 35 mm²
Section flexible cable Max 35 mm²
Rated tightening torque 2 Nm
Double connection YES (up stream and down stram)
Operating temperature -25 +40 °C
Stocking temperature -35 +60 °C
Electrical endurance ≥ 4.000
Mechanical endurance ≥ 10.000
Auxiliaries compatibility No
ReStart compatibility No
Assembly position Any
Ware Number 85362090

Product Data Sheet

Technical characteristics

User guide

CADpro

Advanced design of electrical systems

Show more

CENTRAL

Quotation and Thermal test of modular enclosures

Show more

PROJEX

Low voltage system design

Show more

PBT-Q

Low voltage systems and boards

Show more

ENERGYpro

Boards for building sites, campings-piers and distribution

Show more

PRICE

Estimation of electrical systems

Show more

CE marking

Related products

Gewiss Code
No. of poles
Rated current
Idn
Rated voltage
Auxiliaries compatibility
ReStart compatibility
No. of modules EN 50022

GWD4001

2P

25 A

10 mA

230V

Yes

Yes

2

GWD4002

2P

25 A

30 mA

230V

Yes

Yes

2

GWD4003

2P

25 A

100 mA

230V

Yes

Yes

2

GWD4004

2P

25 A

300 mA

230V

Yes

Yes

2

GWD4022

2P

40 A

30 mA

230V

Yes

Yes

2

GWD4023

2P

40 A

100 mA

230V

Yes

Yes

2

GWD4024

2P

40 A

300 mA

230V

Yes

Yes

2

GWD4025

2P

40 A

500 mA

230V

Yes

Yes

2

GWD4042

2P

63 A

30 mA

230V

Yes

Yes

2

GWD4043

2P

63 A

100 mA

230V

Yes

Yes

2

services

Do you need technical assistance?

Contact us to get the answers to your questions: plant, regulatory or product questions.

Find Gewiss

Are you looking for an installer or a sales point?

Find your trusted dealer or installer.

Write to us

Do you need information on Gewiss products or services?