RESTART RM TOP - TO BE COUPLED WITH MDC/MT+BD/MTC/MT - 230 V - 4 MODULES EN 50022

Code: GW90893

Range: 90 ReStart Range
Automatic reclosing devices

In the event the switch trips, the ReStart devices, after checking the system status, restore the power supply thereby ensuring maximum continuity of service in complete safety.
Available for both residual current circuit breakers and residual current circuit breakers with overcurrent protection, the range is characterized by the Autotest functions, with periodic and automatic control of the residual current protection without interrupting the power supply and PRO with extended control of the system.

Technical Info

Information
Download
Software
Certificates
Description Automatic reclosing device
Code ReStart Rm TOP
Suitable for RCBO's MDC/MT+BD and MCB's MTC/MT
Rated voltage 230 V
Rated current max 63A (MT) max 32A (MDC-MTC)
Rated frequency (Hz) 50Hz
Distribution system TT - TN
No. of modules EN 50022 4
Insulation voltage (Ui) 500 V
Rated impulse
withstand voltage (Uimp)
4 kV
Overvoltage category III
Dielectric strength test voltage between pole and earth 2500 Vac for 1 minute
Type of residual current protection AC - A - A[IR] - A[S]
Rated residual operating current 30 - 300 - 500 - 1000 mA
Operating temperature -25 +60 °C
Stocking temperature -40 +70 °C
Rated non-operating resistance between live parts and earth (Rdo) 8kΩ (30mA) - 2,5kΩ (300-500-1000mA)
Rated operating resistance between live parts and earth (Rd) 16kΩ (30mA) - 5kΩ (300-500-1000mA)
Rated non-operating resistance between live parts (Rcco) 0,3 Ω
Rated operating resistance between live parts (Rcc) 1,8 Ω
Type of contacts 1 x Photomos and 1 x Changeover
Voltage operating Photomos: 5-230 Vac/dc Changeover: 230Vac -30Vdc
Current operating Photomos: 0.6mA (min)-100mA cosϕ=1 (max) Changeover: 1.5mA ac - 0.8mA dc
Use category AC12
Operating modes Photomos: NO/NC/Intermittent Changeover: CO
Terminal section ≤ 2,5 mm²
Rated tightening torque 0,4 Nm
Automatic reclosure for untimely tripping Yes (can be excluded)
Earth failure test Yes (can be excluded)
Short circuit test Yes (can be excluded)
Settable insulation threshold Yes
Continuous system monitoring Yes (can be excluded)
Settable reclosing mode Yes (optional) - automatic, with system control (ReStart function)
- automatic for attempts (adjustable, from 0 to 10 attempts)
- remotely (impulse duration ≥ 200ms)
- automatic reclosing standby time, adjustable from 0 sec. to 1 hour
Ware Number 85362010

User guide

Disposal

Technical characteristics - IT

Technical characteristics - DE

Technical characteristics - EN

Technical characteristics - ES

RESTART

Automatic reclosing devices ReStart

Show more

PBT-Q

Low voltage systems and boards

Show more

CENTRAL

Quotation and Thermal test of modular enclosures

Show more

PROJEX

Low voltage system design

Show more

CADpro

Advanced design of electrical systems

Show more

PRICE

Estimation of electrical systems

Show more

Conformity declaration

CE marking

EQUIPMENT AND NOTES
CHARACTERISTICS: the Rm TOP ReStart allows to:
- set the reclosing mode (reclosing with system check, reclosing by attempts, remote reclosing and excluded reclosing)
- adapt the insulation threshold in according to the associated circuit breaker
- regulate the reclosing time dealy.
The device is equipped with 2 integrated auxiliary contacts of position and/or tripped relay.
NOTE: the ARD must be supplied at 230 V ac phase-neutral.
services

Do you need technical assistance?

Contact us to get the answers to your questions: plant, regulatory or product questions.

Find Gewiss

Are you looking for an installer or a sales point?

Find your trusted dealer or installer.

Write to us

Do you need information on Gewiss products or services?