DOMO CENTER range
Flush-mounting system columns for distribution, Home & Building automation and data
DOMO CENTER transforms the domestic systems into furnishing accessories: a modern design solution that blends with the existing context, centralising and rationalising the existing services - from the most traditional to the most advanced, in a single point with a modularity of up to 320 modules. Also available with personalised design finishes, including the characteristic full-mirror version.
YOUR SEARCH
DOMO CENTER front configuration kit
2700 kit versions - without door
System column front kit with finish panels in white metal RAL 9003 and 2 enclosure - 40 modules
*: 320M maximum available modular space. ACCESSORIES SUPPLIED: 4 functional frames for 80 DIN rail modules (20x4), code GWN1014. 1 metal frame, code GWN1043XB. 2 finish panels without windows, code GWN1066XB. 2 enclosures - 40 DIN rail modules (20x2) with door in smoked transparent glass, code GWN1051XB. NOTES: installation is recommended in areas with a floor-ceiling height of h 2700 mm when the work is complete. Maximum rated current In = 125 A. Flush-mounting back-mounting box to be ordered separately. Reference code GWN1003.
System column front kit with finish panels in white metal RAL 9003 for use as an upright column
*: 40M maximum modular space available (e.g. for terminal block for junction, cross-pieces etc.). SUPPLIED: 1 functional frame for 40 DIN rail modules (20x2), code GWN1012. 3 functional frames supplied with back-mounting plate, code GWN1024. 1 functional frame supplied with back-mounting plate, code GWN1022. 1 metal frame, code GWN1043XB. 2 finish panels without windows, code GWN1066XB. 1 finish panel without windows, code GWN1064XB. NOTES: installation is recommended in areas with a floor-ceiling height of h 2700 mm when the work is complete. Maximum rated current In = 125 A. Flush-mounting back-mounting box to be ordered separately. Reference code GWN1003.
2700 kit versions - with door
System column front kit with door in smoked transparent glass, finish panels in white metal RAL 9003, 2 underdoor enclosures 40 M and underdoor panels white RAL 9003
*: 320M maximum available modular space. ACCESSORIES SUPPLIED: 4 functional frames for 80 DIN rail modules (20x4), code GWN1014. 1 metal frame, code GWN1043XB. 2 finish panels without windows, code GWN1062XB. 2 underdoor enclosures for 40 DIN rail modules (20x2), code GWN1121XB. 4 underdoor panels, code GWN1124XB. 1 door in transparent smoked glass, code GWN1111CF. NOTES: installation is recommended in areas with a floor-ceiling height of h 2700 mm when the work is complete. Maximum rated current In = 125 A. Flush-mounting back-mounting box to be ordered separately. Reference code GWN1003.
System column front kit with mirror finish panels and door, 2 underdoor enclosures 40 M and underdoor panels white RAL 9003
*: 320M maximum available modular space. CHARACTERISTICS: door and panels in metal with integral mirror finish on the entire surface. ACCESSORIES SUPPLIED: 4 functional frames for 80 DIN rail modules (20x4), code GWN1014. 1 metal frame, code GWN1043XB. 2 underdoor enclosures for 40 DIN rail modules (20x2), code GWN1121XB. 4 underdoor panels, code GWN1124XB. 1 door and 2 mirror panels, code GWN1111CP. NOTES: installation is recommended in areas with a floor-ceiling height of h 2700 mm when the work is complete. The door pack with mirror finish include also 2 mirror panels with h = 300 mm. Maximum rated current In = 125 A. Flush-mounting back-mounting box to be ordered separately. Reference code GWN1003.
System column front kit with door and finish panels in white metal RAL 9003, 2 underdoor enclosures 40 M and underdoor panels white RAL 9003
*: 320M maximum available modular space. ACCESSORIES SUPPLIED: 4 functional frames for 80 DIN rail modules (20x4), code GWN1014. 1 metal frame, code GWN1043XB. 2 finish panels without windows, code GWN1062XB. 2 underdoor enclosures for 40 DIN rail modules (20x2), code GWN1121XB. 4 underdoor panels, code GWN1124XB. 1 metal door, code GWN1111XB. NOTES: installation is recommended in areas with a floor-ceiling height of h 2700 mm when the work is complete. Maximum rated current In = 125 A. Flush-mounting back-mounting box to be ordered separately. Reference code GWN1003.
2400 kit versions - without door
System column front kit with finish panels in metal colour RAL 9003 and 1 enclosure - 40 modules
*: 280M maximum available modular space. ACCESSORIES SUPPLIED: 3 functional frames for 80 DIN rail modules (20x4), code GWN1014. 1 functional frame supplied with DIN rails, code GWN1012. 1 metal frame, code GWN1042XB. 2 finish panels without windows, code GWN1066XB. 1 enclosure for 40 DIN rail modules (20x2) with door in smoked transparent glass, code GWN1051XB. NOTES: installation is recommended in areas with a floor-ceiling height of h 2400 mm when the work is complete. Maximum rated current In = 125 A. Flush-mounting back-mounting box to be ordered separately. Reference code GWN1002.
System column front kit with finish panels in white metal RAL 9003 for use as an upright column
*: 40M maximum modular space available (e.g. for terminal block for junction, cross-pieces etc.). ACCESSORIES SUPPLIED: 1 functional frame for 40 DIN rail modules (20x2), code GWN1012. 3 functional frames supplied with back-mounting plate, code GWN1024. 1 metal frame, code GWN1042XB. 2 finish panels without windows, code GWN1066XB. 1 finish panel without windows, code GWN1062XB. NOTES: installation is recommended in areas with a floor-ceiling height of h 2400 mm when the work is complete. Maximum rated current In = 125 A. Flush-mounting back-mounting box to be ordered separately. Reference code GWN1002.
2400 kit versions - with door
System column front kit with door in smoked transparent glass, finish panels in white metal RAL 9003, 1 underdoor enclosure 40 M and underdoor panels white RAL 9003
*: 280M maximum available modular space. ACCESSORIES SUPPLIED: 3 functional frames for 80 DIN rail modules (20x4), code GWN1014. 1 functional frame supplied with DIN rails, code GWN1012. 1 metal frame, code GWN1042XB. 2 finish panels without windows, code GWN1062XB. 1 underdoor enclosure for 40 DIN rail modules (20x2), code GWN1121XB. 4 underdoor panels, code GWN1124XB. 1 door in transparent smoked glass, code GWN1101CF. NOTES: installation is recommended in areas with a floor-ceiling height of h 2400 mm when the work is complete. Maximum rated current In = 125 A. Flush-mounting back-mounting box to be ordered separately. Reference code GWN1002.
System column front kit with mirror finish panels and door, 1 underdoor enclosure 40 M and underdoor panels white RAL 9003
*: 280M maximum available modular space. CHARACTERISTICS: door and panels in metal with integral mirror finish on the entire surface. ACCESSORIES SUPPLIED: 3 functional frames for 80 DIN rail modules (20x4), code GWN1014. 1 functional frame supplied with DIN rails, code GWN1012. 1 metal frame, code GWN1042XB. 1 underdoor enclosure for 40 DIN rail modules (20x2), code GWN1121XB. 4 underdoor panels, code GWN1124XB. 1 door and 2 mirror panels, code GWN1101CP. NOTES: installation is recommended in areas with a floor-ceiling height of h 2400 mm when the work is complete. The door pack with mirror finish include also 2 mirror panels with h = 300 mm. Maximum rated current In = 125 A. Flush-mounting back-mounting box to be ordered separately. Reference code GWN1002.
System column front kit with door and finish panels in white metal RAL 9003, 1 underdoor enclosure 40 M and underdoor panels white RAL 9003
*: 280M maximum available modular space. ACCESSORIES SUPPLIED: 3 functional frames for 80 DIN rail modules (20x4), code GWN1014. 1 functional frame supplied with DIN rails, code GWN1012. 1 metal frame, code GWN1042XB. 2 finish panels without windows, code GWN1062XB. 1 underdoor enclosure for 40 DIN rail modules (20x2), code GWN1121XB. 4 underdoor panels, code GWN1124XB. 1 metal door, code GWN1101XB. NOTES: installation is recommended in areas with a floor-ceiling height of h 2400 mm when the work is complete. Maximum rated current In = 125 A. Flush-mounting back-mounting box to be ordered separately. Reference code GWN1002.
DOMO CENTER components
Back-mounting boxes
Metal flush-mounting back-mounting box for masonry and plasterboard walls
ACCESSORIES SUPPLIED: adjustable feet, masonry template, casing union band and 2 upper and lower cover panels with h=150 mm. CHARACTERISTICS: flush-mounting back-mounting box can be obtained with two coupled casings. Rectangular knockouts on the vertical sides and lower and upper heads open for pipe entrance. Adjustable feet from 0 to 205 mm both on the lower side as well as on the upper side for installation adjustment. APPLICATIONS: flush-mounting back-mounting box, code GWN1002, for applications in areas with a floor-ceiling height of h 2400 mm when the work is complete. flush-mounting back-mounting box, code GWN1003, for applications in areas with a floor-ceiling height of h 2700 mm when the work is complete.
Internal configuration
Functional metal frames equipped with DIN rails for modular devices
ACCESSORIES SUPPLIED: vertical wiring trunking 80x60 mm. Screw kit for fixing the frame on the back-mounting box. CHARACTERISTICS: pre-arrangement for horizontal trunking 30x60 and use of horizontal dividers, code GWN1141.
Functional frames with metal back-mounting plate for fixing non-modular devices
ACCESSORIES SUPPLIED: vertical wiring trunking 80x60 mm. Screw kit for fixing the frame on the back-mounting box. CHARACTERISTICS: pre-arrangement for horizontal trunking 30x60 and use of horizontal dividers, code GWN1141.
APPLICATIONS: multimedia Boards allow the distribution of the services from the DOMO CENTER through the apartment (e.g. internet, phone, satellite TV, etc.). This version is dedicated to big apartments and villas with a huge amount of services and devices that have to be connected. FEATURES: the product is compliant to the CEI 306-2 Guide. ACCESSORIES SUPPLIED: 2 pcs vertical wiring trunking 80x60 mm, 1 kit fixing screws, 1 pc frame with 3 pcs perforated mounting plates (1 pc with 18 Keystone Jack slot), 3 m velcro roll h=16 mm, 6 pcs brackets, 6 pcs self-adhesive cable clips with cable ties, 6 pcs. RJ45 Cat.6 Keystone Jack, 6 pcs patch cord RJ45-RJ45 Cat.6 0,6 m, 1 pc thelephone splitter with 5 RJ11 socket and 5 pcs patch cord RJ11-RJ45, 1 pc multiple socket with 4 Italian/German socket 2P+T 16A. INSTALLATION: the finishing panel GWN1122XB can be used for better aesthetics and protection.
Frames
Modular metal frames for fixing front configuration elements white RAL 9003
ACCESSORIES SUPPLIED: fixing template. CHARACTERISTICS: to fix the frame, it is necessary to first install the internal configuration elements: functional frames and kits for specific functions (network cabling).
Front configuration
40 module enclosure with door in smoked transparent glass Front in white metal RAL 9003
CHARACTERISTICS: reversible door in smoked glass; magnet closure; can be fitted with a safety lock GWN1132. Door opening 170°. ACCESSORIES SUPPLIED: panel for covering the modular devices, 2 module covering masks (6.5 DIN rail modules) milk white colour. Panel closure by the tool for board accessibility.
Panels without windows with design finish in metal - white RAL 9003
CHARACTERISTICS: magnet closure; hinged panels with reversible opening up to 170°. Panel closure requires a tool, for accessibility to the panel. GWN1077XB panel also allows modular equipment to be installed, in addition to the specific home AUTOMATION/video entryphone/burglar alarm device, for a maximum of 40 DIN MODULES. APPLICATIONS: for GW10934 burglar alarm system keyboard.
CHARACTERISTICS: tempered glass; hinged and reversible door with 170° opening and magnet closure; can be fitted with a safety lock code GWN1132. NOTES: To foresee 2 blank panels for aesthetic finishing GWN1062XB.
CHARACTERISTICS: hinged and reversible door with 170° opening and magnet closure; can be fitted with a safety lock code GWN1132. door and panels in metal with integral mirror finish on the entire surface. ACCESSORIES SUPPLIED: 2 panels with mirror finish h = 300 mm.
CHARACTERISTICS: hinged and reversible door with 170° opening and magnet closure; can be fitted with a safety lock code GWN1132. NOTES: To foresee 2 blank panels for aesthetic finishing GWN1062XB.
Underdoor panel with windows in white metal RAL 9003
NOTE: panel closure by the tool for board accessibility. The panels can be used in both without door configuration (under the blank metal panles for aesthetic finishing) and with door configuration (as metal underdoor panels).
APPLICATIONS: for closing doors height h 1500/1800 mm and for enclosure door code GWN1051XB. Lock block to be installed on the metal frame. ACCESSORIES SUPPLIED: 2 keys. NOTES: all the keys and relative locks with the same product code are identical.
Channel crossing the floor slab and back-mounting box coupling device
CHARACTERISTICS: the kit is suppled with 2 safety closings for the frame with relative fixing screws. APPLICATIONS: the kit has to be used with metal blank underdoor panels for aesthetic finishing GWN1062XB, GWN1064XB, GWN1066XB to allow the opening only to qualified personnel.
NOTES: the horizontal divider is used for creating internal separation between circuits of differing voltages on several rows within a single casing. CHARACTERISTICS: vertical divider to be used for back-mounting boxes GWN1002 and GWN1003. Ideal for the segregation of circuits when using the Domo Center as an upright column. Pre-arrangement of up to 3 installable vertical dividers.
We use technical cookies for optimum navigation. By continuing, you agree to use cookies, otherwise you can disable them from your browser.
Field required
Check that the e-mail is not already used or that all the fields have been enhanced
Check your email
The password must contain at least 6 and a maximum of 12 characters, a numeric character and a uppercase letter
Registration is successfully completed
Attention: User name and password do not match
Enter a valid email address
The value does not match
Data modification is successfully completed
To fill the form you must be logged. Please go to
login page
Mail sent successfully
Inscribed
Thank you!
Your request has been sent successfully
Authentication error
Error sending request
Please try again later!
User not found
Integration error
Please contact the administrator
You are already registered at the event
View card
Change Password is successfully completed
The password must contain at least 6 and a maximum of 12 characters, a numeric character and a uppercase letter
Please enter the mail in the appropriate field
Error sending request. Please try again later!
Saving in the list
Insert the name of the catalog
Expired
For the download of the file you have to choose a subtype during registration, go on modify profile and choose it!
For the download of the file you have to be a professionist installer or wholesaler. Upgrade your profile on my profile page!
For the download of the file you have to be a professionist installer or wholesaler, a designer or lighting designer. Upgrade your profile on my profile page!
GO
Verify code is expired, please try to login
The date must be of the indicated format